Quick answer
The most common causes are a thermostat set wrong, a clogged air filter, a tripped breaker on the outdoor unit, a frozen indoor coil, a failed capacitor, or low refrigerant. The first four you can check yourself. The last two need a technician.
1. The thermostat is set wrong
It sounds too simple, but it's the first thing to rule out.
- Is it set to cool, not heat, auto or fan?
- Is the setpoint below the room temperature?
- If the fan is set to on instead of auto, it blows air even when the AC isn't cooling, which can feel warm.
- If the screen is blank, replace the batteries.
2. The air filter is clogged
A dirty filter chokes airflow. The system can't move enough air across the cold coil, so cooling drops off and the coil can freeze. In Houston, where the AC runs most of the year, check the filter monthly and replace it as needed.
3. The outdoor unit isn't running
Go outside while the AC is calling for cooling. If the indoor fan is blowing but the outdoor unit is silent, or the outdoor unit hums but its fan isn't spinning:
- Check the breaker panel for a tripped breaker labeled AC or condenser. Reset it once. If it trips again, stop and call a technician.
- Check the disconnect box on the wall next to the outdoor unit.
If the outdoor unit hums but the fan doesn't spin, the capacitor has often failed. See #5.
4. The indoor coil is frozen
If you see ice on the copper lines or the indoor unit, turn the system off at the thermostat and set the fan to on to thaw it. That can take several hours. Then replace the filter and try again. If it freezes again, there's an underlying problem. Read why ACs freeze up.
5. A failed capacitor
The capacitor gives the compressor and outdoor fan motors the jolt they need to start. In Houston heat, it's one of the most common parts to fail. Sometimes it looks swollen or domed on top, or it leaks oil.
A capacitor can hold a dangerous electrical charge even with the power off. Don't touch, test or replace it yourself. It's a quick repair for a technician.
6. Low refrigerant
Refrigerant doesn't get "used up." If it's low, there's a leak. Signs include ice on the lines, weak cooling and a hissing sound. Handling refrigerant requires EPA certification, and the leak needs to be found and fixed, not just topped off.
7. A dirty outdoor coil or blocked unit
The outdoor unit needs to release heat. Grass clippings, leaves, cottonwood fluff or a fence too close can trap it. Keep about two feet clear around the unit. A deep coil cleaning is part of a spring tune-up.
When to call
Call a technician if the breaker trips again, the coil freezes again, the outdoor unit hums without the fan spinning, you suspect a refrigerant leak, or you smell burning. Book online or call 832-544-5130.
If you'd like help working through the safe checks, our DIY assistant walks you through them for $29.99, and that comes off the service call if you still need us.